Base build

Base build testingLB500LB600LB700ACLB 200Standard or solid-state switching

End-of-line

End-of-line testingLCLB 160LCLB 240ACLB 60

Applications

Cooling

Chillers and cooling plantStatic and dynamic load testing

Power

UPS systemsGeneratorsSwitchgear and power qualityProtection settings

Explained

Liquid coolingGPU load testingWater qualityLoop monitoringCommissioning

Equipment

Commissioning equipment

Manifold trolleyFlushing & refill cart

Tools

The full rangeSizing calculatorDatasheets

Services

Commissioning supportLoad bank hireHigh load simulationBespoke load banksSupply and installationMaintenance and repairDeployment and managementBuy or hireProjects

Company

AboutPartnersProjectsAcademyNewsEventsFAQ Speak to the team
Home/Products/End-of-line testing

AI liquid GPU emulators for end-of-line testing

True rack-level heat and electrical replication for end-of-line testing, with solid-state switching, before a single GPU is installed.

PowerLoad AI liquid GPU emulator
160kWLCLB 160, per unit
240kWLCLB 240, per unit
60kWAir emulator, ACLB 60
250Units on one controller

The load moves fast, in both directions

AI has changed the behaviour of the load, not just its size. When it rises or drops suddenly, the CDU, pumps, valves, sensors and controls have to respond, then the cooling plant, UPS and generators behind them. A steady load bank cannot show you that.

Steady-state load bank Real GPU transient
How it works

What the emulators do

Fast load changes

Solid-state switching steps the load far faster than contactor-based banks, in both directions.

Test the whole response

The test covers every part of the cooling and power chain, not only the capacity of the loop.

Cover liquid and air

Not every part of a server is liquid cooled, so the ACLB 60 recreates the air-cooled heat as well.

Where it sits

Testing at the rack

Entry Switchgear Conventional test Emulator Rack PowerLoad tests here Data hall row

Power quality and cooling are proven at the point the GPUs will run.

End-of-line testing

The emulators

Work out how many emulators a hall needs with the sizing tool. Testing the cooling plant while the hall is still being built? See the base build range.

Purchase or rental

Buy the emulators or hire them

Every emulator is available to buy or to hire, sized to the test plan.

PurchaseOWN THE FLEET
RentalHIRE FOR THE TEST
Choose it for
Repeat testing across several halls and sites
One project or one test window
What you get
The units, the controller, training and manuals for your team
The units for the length of the test, delivered to site

Ask about purchase or rental

Watch

The kit, explained

Mirroring how GPUs draw
What the GPU emulator is
Replicating GPU behaviour
Testing before the hardware
Solid-state switching
FAQ

AI liquid GPU emulators, answered

The LCLB 160 and LCLB 240 both support GB200 and GB300, and the LCLB 240 is Rubin ready. Give us your design and IT load and we will size the emulation to match.

A liquid-cooled load bank that replicates how a GPU rack will behave, for heat and for electrical load, at the rack. The load moves quickly in both directions, so commissioning teams can see whether the CDU, pumps, valves, controls, cooling plant, UPS and generators respond as they should before the GPUs are installed.

A base build load bank gives a dependable, controllable heat load that proves capacity. A GPU emulator adds solid-state switching so the load moves the way real compute moves, up and down, and the whole chain has to respond.

Yes. The emulator sits at the rack position instead of at the building entry, so power and cooling are tested where the GPUs will run.

Yes. The AI liquid GPU emulators are available to hire. Speak to the team about availability for your project.

Downloads

End-of-line datasheets

Electrical and hydraulic specification, control detail, dimensions and connections, as a PDF with no email gate.

Plan end-of-line testing for your project

Give us your design and IT load, and we replicate its live performance before it goes live.