Built to test the IT electrical and heat load in hyperscale liquid-cooled AI data centres, from 500kW to 700kW per liquid-cooled unit, plus the portable 200kW ACLB 200.
Base build testing proves capacity. When the specification asks for it, solid-state switching adds a response test, with the load stepping fast enough to follow transient electrical spikes and surges.
Every unit has standard switching. Solid-state is an optional extra on the liquid-cooled units. How solid-state switching works →
One design in three sizes, with the same stainless steel internals and controls. Only the pipework and power supply change, from 4 inch at 500kW to 5 inch at 700kW.
LB500
500kWPer unit
Stainless steel internals, PG25 compatible, with remote monitoring.
See the LB500
LB600
600kWPer unit
600kW of guaranteed heat output on the same 4 inch flow and return.
See the LB600 Newest
LB700
700kWHighest single-unit capacity
The highest single-unit capacity on 5 inch flow and return, with 1kW switching when solid-state is fitted.
See the LB700
ACLB 200
200kWPortable, air-cooled
Load steps from 1kW on a wheeled unit.
See the ACLB 200
The entry unit of the range, with remote monitoring and recorded test data for sign-off. Two LB500s on a manifold give 1MW.
600kW of guaranteed heat output with a drained weight under 800kg. Solid-state switching is available as an option.
The highest single-unit capacity in the range, in the same footprint as the LB500 and LB600. Stainless steel internals and integrated temperature control keep PG25 below 45°C, so it runs on the PG25 loops most AI halls use. Optional solid-state switching gives 1kW switching for fine load resolution.
A wheeled air-cooled unit for smaller loads and power-side tests, with load steps from 1kW.
Once the base build is proven, the end-of-line range replicates how the GPUs will behave at each rack position, before they are installed.
Every unit is assembled and tested in-house.
Every part the coolant touches is stainless steel.
Runs on PG25, chilled or deionised water loops.
An optional extra for transient load tests.
One controller drives the whole fleet.
Live flow, temperature and pressure readings.
Pressure drop is set to match the design under test.
Set the temperature rise across the load bank to match the design.
Checked as it is captured and kept for sign-off.
Each unit is built to suit the site supply.
Coolant connections are placed to suit the hall.
The ACLB 200 is a wheeled 200kW unit.
A liquid-cooled load bank rejects its heat into a coolant loop rather than into the air, so it connects directly to the data hall cooling infrastructure. In base build testing it proves the capacity of the chillers, CDU and risers while the hall is being built. The base build range runs from the 200kW ACLB 200 to the 700kW LB700.
They are the same design. The LB500 is rated at 500kW and the LB600 at 600kW, both on 4 inch flow and return with stainless steel internals and PG25 compatibility. Solid-state switching is an optional extra on either, not a separate model.
The LB700 is rated at 700kW and is the highest-capacity single unit. It runs on 5 inch flow and return, and optional solid-state switching gives 1kW switching for fine load resolution.
The ACLB 200 is a portable 200kW air-cooled load bank with load steps from 1kW. It is part of the base build range. The full specification is on the air-cooled load banks page.
The PowerLoad controller networks up to 250 load banks, monitored and driven from a single point with live flow, temperature and pressure and exportable test data.
Yes. The liquid-cooled load banks are available to hire. Speak to the team about availability for your project.
Full specification, flow rates and connection detail. Published documents download straight away; ask us for the rest and we will send the current revision.
500kW per unit, rejecting heat straight into the coolant loop. Full specification, flow rates and connection detail.
Download LB600The 600kW liquid-cooled load bank. Full specification confirmed per project.
Download LB700The highest-capacity single unit in the range, on 5 inch flow and return with optional 1kW solid-state switching.
DownloadTell us the IT load and the programme. We will size the kit around it.