AI grade liquid: base build
Stainless steel internals, PG25 compatible, and up to 250 units on one controller, for chillers, CDUs and risers.
AI has changed the behaviour of the load. Our UK-built load banks and GPU emulators replicate it, so you can prove your cooling and power respond before the GPUs arrive. Testing the future of data centre cooling.
A one megawatt hall used to mean one megawatt of steady load and heat. GPU racks now swing from 25 to 100 percent in milliseconds, and drop again just as fast, so the whole system has to respond in both directions.
So the test is no longer only capacity. It is how the CDUs, pumps, valves, controls and power chain respond when the load changes.
Not just cooling capacity: the cooling and the power, with load rising and falling. These are the six things we help you test.
Cooling has to follow the load down as well as up. Test it in both directions.
Static tests prove capacity. Dynamic tests show how the system responds when load changes.
Built for smooth loads, so test them against the rapid changes of AI compute.
Mechanical systems take time to respond. Transient load tests show the gap.
Load swings cause voltage dips and spikes that a steady load does not show.
Protection reacts to spikes, not average load. Test settings against transient electrical spikes.
Base build units prove the heat load and cooling plant while the hall is built. End-of-line emulators replicate true rack-level heat and electrical load, as the GPUs will behave. The flushing and refill cart cleans and fills the loop for both.
Stainless steel internals, PG25 compatible, and up to 250 units on one controller, for chillers, CDUs and risers.
Cleans and fills the loop before the load test, and flushes GPU racks one at a time once the hall is live.
True rack-level heat and electrical replication at each rack, before the GPUs are installed.
Distribution and balancing for the coolant loop, for either range.
Partnerships, projects and where to meet the PowerLoad team.
Network up to 250 units on one controller. Monitor flow, temperature and pressure live, and export test data for the commissioning record.
PowerLoad brings together experience in power, cooling, load banks, flushing and commissioning. When you work with us, you work with a team that understands the data centre and what you are trying to prove, not only a company that can supply a load bank.
Our CEO, Brendan Leonard, has more than 40 years in data centre cooling. In this video he explains how cooling has evolved, and why the way it is tested has to change with it.
Give us your design and we replicate its live performance before the hall goes live. Commissioning teams know the infrastructure will work when the equipment goes in.
We work with our customers to de-risk the project.
Real liquid-cooled load bank deployments on live data centre projects, with further work on record in Paris and Munich.
The commissioning, mechanical and HVAC teams on site.
Testing a hall before the hardware and the tenant arrive.
Delivering the hall to programme, with the testing planned in.
Test results to check the design performs.
25 explainers on liquid cooling, load testing and commissioning, written out in full and searchable by what is said on camera.
News, partnerships and events from PowerLoad.
Regional partnership
UK-engineered load banks and GPU emulation, now delivered and supported in region with one of the Middle East's largest independent commissioning providers.
Read the story →
Alliance
Event
Talk to us about replicating your design's live performance before the hall goes live.