Home/Projects/Frankfurt, Germany
Germany · Retrofit to liquid cooled · CDU and rack level testing

Three 500kW banks,
one manifold trolley

A retrofit to liquid-cooled operation in Frankfurt, commissioned at the CDU and at rack level.

Project details

Client
Global Colocation Giant
Location
Frankfurt, Germany
Solution provided
CDU & Rack Level Testing
Project type
Load Bank Commissioning

As recorded by PowerLoad. Client names are not published.

3500kW LB500 banks
500kWPer unit
2Load tests on the record
PowerLoad 500kW liquid-cooled load banks side by side
Scope

What is on the record

Three banks of the same model, served through one manifold trolley.

  • Retrofit to Liquid Cooled
  • AI GPU Rack Level Testing
  • Liquid Cooled
  • 3 x 500kW LB500 Loadbank
  • Commissioning Manifold Trolley
  • Full Load Test
  • Client Load Test
  • Advanced Commissioning Reporting

Reproduced from PowerLoad's own project record. Nothing has been added to it.

A stainless PowerLoad commissioning manifold with valve assemblies
The equipment

A 500kW liquid-cooled load bank

The 500kW liquid-cooled load bank has a dual 400/400amp supply and full stainless steel internals, and is engineered for direct cooling loop integration, so it validates the CDU, manifold and coolant path while it applies the electrical load.

Results are captured through the controller and exported as commissioning reporting.

Specification from the PowerLoad Liquid-Cooled Load Banks page. Not specific to this project.

Talk to us about your hall
On the record

The equipment listed

LB500 Liquid Load Bank 3 x 500kW

LB500 Liquid Load Bank

Direct cooling loop integration, dual 400/400amp supply, stainless internals.

On the record
Commissioning Manifold Trolley 1 trolley

Commissioning Manifold Trolley

Distribution into the coolant loop from a single connection point.

On the record
The workflow

Where the trolley sits in the sequence

This is the PowerLoad commissioning sequence the manifold trolley belongs to. It is how the equipment is designed to be used, not a log of this project.

Flush and fill

The cart circulates coolant through a 25 micron filter to clear swarf and debris, vents trapped air, then charges the loop from its 250L tank.

Distribute and regulate

The trolley distributes the riser feed to regulated outlets, one per rack, each with a flow meter and pressure sensor.

Load and prove

With the loop clean and balanced, the load bank applies load at the rack. Flow and pressure feed back over I/O Link and BACnet.

The kit

What it looks like on the floor

PowerLoad 500kW liquid-cooled load banks
PowerLoad 500kW liquid-cooled load banks
500kW liquid-cooled bank, front three-quarter
500kW liquid-cooled bank, front three-quarter
Stainless manifold detail
Stainless manifold detail
Cabinets built and run up in the UK
Cabinets built and run up in the UK
The valve row on a commissioning manifold
The valve row on a commissioning manifold

PowerLoad equipment, photographed in our own workshop and on our own sites. Client halls are commercially confidential, so what you see here is the kit, not the customer's building.

More projects

The other halls

Planning a similar project?

Tell us the hall, the density and the programme. We will size the load banks, emulators and commissioning support around it.